Evolução da capacidade funcional durante 18 anos num doente em hemodiálise crónica: relato de caso

Autores

  • Sónia Casado Tecnologia e Serviços Médicos SA. Research Centre for Active Living and Wellbeing (LiveWell) https://orcid.org/0000-0002-0868-2195
  • Eugénia Mendes Instituto Politécnico de Bragança, Bragança, Portugal. Research Centre for Active Living and Wellbeing (LiveWell) https://orcid.org/0000-0001-6528-4284
  • Leonel Preto Instituto Politécnico de Bragança, Bragança, Portugal. Research Centre for Active Living and Wellbeing (LiveWell) https://orcid.org/0000-0002-8126-7051
  • Jorge Morais Instituto Politécnico de Bragança, Bragança, Portugal. Research Centre for Active Living and Wellbeing (LiveWell) https://orcid.org/0000-0002-6885-0648
  • Carolina Vila-Chã Instituto Politécnico Cávado e Ave, Barcelos, Portugal. Centro de Investigação e Inovação em Desporto
  • André Novo Instituto Politécnico de Bragança, Bragança, Portugal. Research Centre for Active Living and Wellbeing (LiveWell) https://orcid.org/0000-0001-8583-0406

DOI:

https://doi.org/10.33194/rper.2026.46106

Palavras-chave:

Capacidade Funcional, Hemodiálise, Reabilitação, Enfermagem em Reabilitação

Resumo

Introdução: A Doença Renal Crónica e a hemodiálise impactam a capacidade funcional, associadas a sarcopenia e sedentarismo, fatores de risco para maior morbilidade e mortalidade. A integração sistemática de testes funcionais na vigilância de doentes hemodialisados pode apoiar a identificação precoce de declínio e o planeamento de intervenções de reabilitação individualizadas.

Objetivo: Descrever a evolução da capacidade funcional, ao longo de 18 anos, de um utente hemodialisado.

Metodologia: Estudo descritivo, tipo relato de caso, orientado pelas Case Report Guidelines. Foram realizadas três avaliações da capacidade funcional (2007, 2012 e 2025) com Sit-to-Stand Test em 30 segundos (STS 30s), o Timed Up and Go Test (TUG) e a força de preensão manual (HGS).

Resultados: Participou um homem, atualmente com 55 anos. Observou-se estabilidade do STS 30s entre 2007 e 2012, com 19 repetições, seguida de declínio em 2025 (13 repetições). No TUG verificou-se aumento progressivo do tempo, de 6 segundos em 2007 para 10 segundos em 2025. Na força de preensão manual registaram-se reduções marcadas: na mão direita, de 27Kgf em 2007 para 8kgf em 2025; na esquerda, de 29 kgf para 8kgf.

Discussão: Observou-se uma redução clinicamente relevante da capacidade funcional, mais acentuado no último momento de avaliação, em consonância com a literatura sobre o declínio funcional em doentes hemodialisados.

Conclusão: Verificou-se uma redução consistente e acentuada da funcionalidade ao longo dos 18 anos, reforçando a importância de programas estruturados de reabilitação para mitigar os efeitos do envelhecimento, da inatividade e do estado catabólico associado à hemodiálise.

 

Downloads

Não há dados estatísticos.

Referências

1. Hall RK, Rutledge J, Luciano A, Hall K, Pieper CF, Colón-Emeric C. Physical Function Assessment in Older Hemodialysis Patients. Kidney Med. 2020 Jul 1;2(4):425–31. doi:10.1016/j.xkme.2020.03.008

2. Roshanravan B, Patel K V. Assessment of physical functioning in the clinical care of the patient with advanced kidney disease. Semin Dial. 2019 Jul 1;32(4):351–60. doi:10.1111/sdi.12813 PubMed PMID: 31044471.

3. Bulbul E, Namoglu SS. The frailty in older hemodialysis patients and associations with depression, functional status, dialysis adequacy. Therapeutic Apheresis and Dialysis. 2024 Oct 1;28(5):727–34. doi:10.1111/1744-9987.14164 PubMed PMID: 38828537.

4. Chae TS, Kim DS, Ko MH, Won YH. Effect of Pre- and Post-Dialysis Exercise on Functional Capacity Using Portable Ergometer in Chronic Kidney Disease Patients. Ann Rehabil Med. 2024;48(4):239–48. doi:10.5535/arm.240005

5. Cruz-Jentoft AJ, Bahat G, Bauer J, Boirie Y, Bruyère O, Cederholm T, et al. Sarcopenia: Revised European consensus on definition and diagnosis. Age and Ageing. Oxford University Press; 2019. p. 16–31. doi:10.1093/ageing/afy169 PubMed PMID: 30312372.

6. Figueiredo PHS, Veloso LR de S, Lima MMO, Vieira CFD, Alves FL, Lacerda ACR, et al. The reliability and validity of the 30-seconds sit-to-stand test and its capacity for assessment of the functional status of hemodialysis patients. J Bodyw Mov Ther. 2021 Jul 1;27:157–64. doi:10.1016/j.jbmt.2021.02.020 PubMed PMID: 34391227.

7. Furlanetto KC, Correia NS, Mesquita R, Morita AA, do Amaral DP, Mont’Alverne DGB, et al. Reference Values for 7 Different Protocols of Simple Functional Tests: A Multicenter Study. Arch Phys Med Rehabil. 2022 Jan 1;103(1):20-28.e5. doi:10.1016/j.apmr.2021.08.009 PubMed PMID: 34516997.

8. Riley DS, Barber MS, Kienle GS, Aronson JK, von Schoen-Angerer T, Tugwell P, et al. CARE guidelines for case reports: explanation and elaboration document. J Clin Epidemiol. 2017 Sep 1;89:218–35. doi:10.1016/j.jclinepi.2017.04.026 PubMed PMID: 28529185.

9. Gadaen RJR, Kooman JP, Cornelis T, Van Der Sande FM, Winkens BJ, Broers NJH. The Effects of Chronic Dialysis on Physical Status, Quality of Life, and Arterial Stiffness: A Longitudinal Study in Prevalent Dialysis Patients. Nephron. 2021 Jan 1;145(1):44–54. doi:10.1159/000510624 PubMed PMID: 33108785.

10. Thompson S, Stickland MK, Wilund K, Gyenes GT, Bohm C. Exercise Rehabilitation for People With End-Stage Kidney Disease: Who Will Fill the Gaps? Canadian Journal of Cardiology. Elsevier Inc.; 2023. p. S335–45. doi:10.1016/j.cjca.2023.08.011 PubMed PMID: 37597748.

11. de Villar LOP, Martínez-Olmos FJ, Junqué-Jiménez A, Amer-Cuenca JJ, Martínez-Gramage J, Mercer T, et al. Test-retest reliability and minimal detectable change scores for the short physical performance battery, one-legged standing test and timed up and go test in patients undergoing hemodialysis. PLoS One. 2018 Aug 1;13(8). doi:10.1371/journal.pone.0201035 PubMed PMID: 30133445.

12. Rosa CS da C, Nishimoto DY, Souza GD e., Ramirez AP, Carletti CO, Daibem CGL, et al. Effect of continuous progressive resistance training during hemodialysis on body composition, physical function and quality of life in end-stage renal disease patients: a randomized controlled trial. Clinical Rehabilitation. SAGE Publications Ltd; 2018. p. 899–908. doi:10.1177/0269215518760696 PubMed PMID: 29504416.

13. Lein DH, Alotaibi M, Almutairi M, Singh H. Normative Reference Values and Validity for the 30-Second Chair-Stand Test in Healthy Young Adults. Int J Sports Phys Ther. 2022;17(5):907–14. doi:10.26603/001c.36432 PubMed PMID: 35949374.

14. da Silva Almeida K, Costa NS, Lima BN, Dos Reis Neves JL, Pereira Barreto LG, de Jesus Freitas L, et al. “Sit-to-stand test to assess muscle strength after intradialytic exercises in chronic kidney disease patients: A systematic review with meta-analysis.” Journal of Bodywork and Movement Therapies. Churchill Livingstone; 2025. p. 347–58. doi:10.1016/j.jbmt.2025.05.030 PubMed PMID: 40954601.

15. Rikli RE, Jones CJ. Senior Fitness Test Manual [Internet]. Second Edition. Human Kinetics; 2013 [cited 2025 Nov 10]. Available from: https://books.google.pt/books?id=NXfXxOFFOVwC&lpg=PP1&hl=pt-PT&pg=PP1#v=onepage&q&f=false

16. Preto LSR, Gomes JRL, Novo AFMP, Mendes MER, Granero-Molina J. Effects of a Rehabilitation Nursing Program on the Functional Fitness of Institutionalized Elderly. Revista de Enfermagem Referencia. 2016 Mar 1;4(8):55–63. doi:10.12707/RIV15019

17. Wang YC, Bohannon RW, Li X, Sindhu B, Kapellusch J. Hand-grip strength: Normative reference values and equations for individuals 18 to 85 years of age residing in the United States. Journal of Orthopaedic and Sports Physical Therapy. 2018 Sep 1;48(9):685–93. doi:10.2519/jospt.2018.7851 PubMed PMID: 29792107.

18. Duarte MP, Nóbrega OT, Vogt BP, Pereira MS, Silva MZC, Mondini DR, et al. Reference values for handgrip strength, five times sit-to-stand and gait speed in patients on hemodialysis. Nephrology Dialysis Transplantation. 2025 May 1;40(5):987–96. doi:10.1093/ndt/gfae232 PubMed PMID: 39415426.

19. Ashby D, Borman N, Burton J, Corbett R, Davenport A, Farrington K, et al. Renal Association Clinical Practice Guideline on Haemodialysis. BMC Nephrology. BioMed Central Ltd.; 2019. doi:10.1186/s12882-019-1527-3 PubMed PMID: 31623578.

20. Ye L, Tang X, Zhang H, Ge S, Yin L, Zhou Y, et al. Prevalence and risk factors of pre-frailty and frailty in maintenance haemodialysis patients in China: A cross-sectional Study. J Adv Nurs. 2023 Sep 1;79(9):3522–34. doi:10.1111/jan.15676 PubMed PMID: 37186471.

21. Casado SAC, Mendes MER, Preto LSR, Vila-Chã CJF, Novo AFMP. Effect of inspiratory muscle training in hemodialysis patients: a systematic review of randomized controlled trials. Disability and Rehabilitation. Taylor and Francis Ltd.; 2025. doi:10.1080/09638288.2025.2554947

22. HEPA Project Consortium. HEPA (Health Enhancing Physical Activity)-Health and Fitness Assessment for Seniors Educational Modules Manual (IO2). Zagreb; 2021.

23. Deligiannis A, D’Alessandro C, Cupisti A. Exercise training in dialysis patients: impact on cardiovascular and skeletal muscle health. Clinical Kidney Journal. Oxford University Press; 2021. p. II25–33. doi:10.1093/ckj/sfaa273 PubMed PMID: 33981417.

24. Villanego F, Naranjo J, Vigara LA, Cazorla JM, Montero ME, García T, et al. Impacto del ejercicio físico en pacientes con enfermedad renal crónica: revisión sistemática y metaanálisis. Nefrología. 2020 May;40(3):237–52. doi:10.1016/j.nefro.2020.01.002

25. Trombim IC, Góes CR de, Vogt BP. Assessment of muscle strength and physical performance in patients on maintenance hemodialysis: Before or after the dialysis session? Nutrition. 2025 Oct 1;138. doi:10.1016/j.nut.2025.112833 PubMed PMID: 40450843.

Downloads

Publicado

2026-06-20

Como Citar

1.
Claro Casado SA, Rodrigues Mendes ME, São Romão Preto L, Estrela Morais JF, Felix Vila-Cha CJ, Morais Pinto Novo AF. Evolução da capacidade funcional durante 18 anos num doente em hemodiálise crónica: relato de caso. Rev Port Enf Reab [Internet]. 20 de junho de 2026 [citado 11 de julho de 2026];9(1):e46106. Disponível em: https://rper.pt/article/view/46106

Edição

Secção

Artigo original reportando investigação clínica ou básica